61 13 ... Crimping Micro Power Quadlock Contacts (MPQ)
Special tools required:
- 61 4 320
To crimp MPQ contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 325 (2) from crimping set 61 4 320 . See 61 4 320 CRIMPING SET WITH PLIERS
NOTE:
Pliers (1) open automatically as far as they will go when handles are pressed together.
Open pliers (1).
NOTE:
Place contact (2) with utmost care in designated nest (observe cable cross-section) in crimping head (3). Make sure it is exactly positioned.
Place MPQ contact (2) in crimping head (3).
Close pliers (1) one notch.
NOTE:
Follow procedure for cutting and stripping insulation
from cables. See 61 13 CUTTING TO LENGTH AND STRIPPING INSULATION FROM CABLES
Insert stripped cable (2).
Close pliers (1) fully.
Open pliers (1) and remove cable (2).
NOTE:
Check contact for correct crimping.