61 13 ... In-Line Plugs, 30-Pin, Hybrid System MQS/MPQ
Manufactured by AMP: The following contact types without strand sealing can be fitted in the plug housings:
- MQS (Micro Quadlock System)
- MPQ, width 2.8 mm (Micro Power Quadlock)
- MPQ, width 5.2 mm (Micro Power Quadlock)
Socket housing:
Raise lock (1) on housing (2).
Push contact carrier (3) from rear out of housing (2).
Hold down retaining hook (1) of socket contact in opening of contact carrier with a small screwdriver.
Pull wire with socket contact in direction of arrow as far as secondary lock (2).
Hold down retaining hook in secondary lock (1) again and pull cable with socket contact (2) completely out of contact carrier (3).
Pin housing:
Contacts 1 ... 13 and 19 ... 27:
Raise locking slide (1) on both sides (2) of housing and detach.
Contacts 14 ... 18 and 28 ... 30:
Pull slide (1) outwards completely.
Raise lock (2) on housing.
Pull contact carrier (3) out of housing.
The pin contacts are pulled out of a contact carrier as described under "Socket housing".