Service Information
The following charts show the different systems/user functions and components used in the climate control systems of the F01/F02.
SYSTEM FUNCTION CHART
| System Functions | IHKA/FKA |
|---|---|
| IHKA Control Unit | X |
| FKA Control Unit | X |
| HKA Control Unit | |
| Control and adjustment points | 4 |
| Temperature zones | 4 |
| Air flow rate zones | 4 |
| Airflow distribution zones | 4 |
| AUTO programs with 5 intensity levels | 3 |
| Front Airflow stratification | 2 |
| Rear Airflow stratification | 2 |
| Air ionizer for evaporator disinfection | X |
| Variable airflow focus | X |
| Fresh air/recirculated air function, AUC | X |
| Cold start interlock | X |
| Start anti-misting | X |
| Anti-misting | X |
| Defrost | X |
| Max heating | X |
| Max cooling | X |
| Max A/C | X |
| Solar compensation | X |
| Residual heat | X |
| ALL function, 4 zones | X |
| OFF function | X |
| Rear OFF function | X |
| A/C compressor function manual cut-out | X |
| Front interior temperature sensor (IHKA) | X |
| Rear interior temperature sensor (FKA) | X |
| Evaporator temperature sensor | 1 |
| Refrigerant pressure sensor junction box electronics, JB | X |
| Heater matrix temperature sensor | 2 |
| Air outlet temperature sensor | 6 |
| AUC sensor, JB | X |
| Solar sensor | X |
| Condensation sensor | X |