67 62... Notes on initializing power windows: Notes
NOTE:
Initialization
is performed on the power window switch of the relevant door.
Initialization comprises:
- Normalization
- Learning characteristic curve
With normalization, the mechanical end stops of the power window regulator are recorded and stored.
The characteristic curve is learnt immediately after normalization.
When the characteristic curve is learnt, the mechanical closing forces of the power windows are recorded and stored for correct operation of the anti-trapping mechanism.
Initialization, i.e. normalization and learning of characteristic curve, is performed in a continuous operation.
NOTE:
An initialization
must be performed:
- In the event of malfunctions, e.g. no one-touch function, no opening or no convenience function possible.
- After the power windows drive or door module has been replaced.
- After work is carried out on the power windows mechanism.
WARNING:
There is no anti-trap mechanism during initialization.
Necessary preliminary tasks:
- Vehicle stationary
- Sufficient battery voltage available / connect charger if necessary
- Terminal "15" switched on
- All doors closed
- F12 up to 02/2012 soft top open, from 03/2012 soft top closed
Operating procedure for initialization (manual):