Reference Run
In order to determine the zero position, the adaptive headlight performs a reference run depending on the current position of the swivel module.
To avoid a hysteresis during calibration, the swivel module always moves from the same side over the zero position sensor.
This is achieved in that the swivel module is always moved to the same side of the zero position sensor before switching off the adaptive headlight.