41 00... General Cementing Instructions
IMPORTANT:
Conform with safety precautions
. See 41 00... SAFETY AT WORK or 41 00... INFORMATION ON HAZARDS !
- The bonding surfaces must be kept free of all types of dirt and contamination. Avoid leaving fingerprints.
- Cleanliness is the golden rule for all bonds!
- Cleaning agent: isohexane
Expiry date of adhesive:
- The adhesive cartridge is marked with a date.
- Do not use the adhesive after this date.
2-component adhesive application:
- Insert adhesive cartridge in adhesive gun, remove cap and allow some adhesive to emerge. Strip adhesive components uniformly and attach mixing tube.
- Allow approx. 1 mixer length of mixed adhesive to emerge (there must be no smearing of colors). Only then apply the mixed adhesive to one side of the bonding surface.
Adhesive disposal:
- Hardened adhesive is disposed of as normal waste.
- Empty adhesive cartridges are disposed of as normal waste.
- Non-hardened adhesives and mixtures of adhesive and solvent and the like must be disposed of as hazardous waste.
These regulations apply to the Federal Republic of Germany .
For other countries, comply with the (possibly differing) nationally applicable regulations .