61 13... Crimping Micro Quadlock System contacts (MQS)
To crimp MPQ contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320.
NOTE:
Pliers (1) open automatically as far as they will go when handles are pressed together.
Open pliers (1).
Fold up contact carrier (2).
Insert MQS contact (3) in contact carrier (2).
Fold back contact carrier (2).
NOTE:
Follow procedure for CUTTING AND STRIPPING INSULATION
from cables.
Close pliers (1) one notch.
Insert stripped cable (2).
Close pliers (1) fully.
Open pliers (1).
Open contact carrier (2) gently and carefully remove MQS contact.
IMPORTANT:
Check contact for correct crimping.