Condition for fault identification
Voltage precondition
- Vehicle voltage between 9V and 16V
Temperature condition
- Engine temperature greater than 80 °C
Time condition
- None
Other preconditions
- Engine ON
- No fault code memory entries that could cause a fault in the fuel-air mixture.
Terminal status
- Terminal 15 on