Chart A2 - Main Valve

Main valve is a solenoid valve, located inside hydraulic unit. Valve is activated by EBCM (pin No. 18) to provide modulated boost pressure to front hydraulic wheel brake circuits. Valve is grounded internally to hydraulic unit. Normal resistance is 2-5 ohms.

Fig 1: Main Relay Grounding Schematic
G56121
Fig 2: Flow Chart A2, Code 21 - Main Valve
G56122
Fig 3: Flow Chart A2, Code 21 - Main Valve (1 of 2)
GB0010944
Fig 4: Flow Chart A2, Code 21 - Main Valve (2 of 2)
GB0010945