Powertrain Control Module (PCM)
- Ignition Voltage
-
Displays 0.0-25.5 V. This parameter is the system voltage measured by the PCM at the PCM ignition input when the ignition switch is in the RUN position.
- IMS
-
Displays Park, Park/Reverse, Reverse, Reverse/Neutral, Neutral, Neutral/Drive 4, Drive 4, Drive 4/Drive 3, Drive 3, Drive 3/Drive 2, Drive 2, Drive 2/Drive 1, Drive 1, Invalid or Open. The IMS Range display represents a decoded status of the four inputs from the IMS. This range includes all possible in-between gear states as well as the detent gear states. The combination of IMS inputs to the PCM are used by the PCM in order to determine what position the manual valve is in at any time.