Installation Procedure
- Clean the BPMV/EBCM mating surface using denatured alcohol and a clean towel.
- Install the EBCM (1) to the BPMV.
- Install the 6 screws that attach the EBCM to the BPMV.
Tighten:
- Tighten the top 4 mounting screws to 5 N.m (44 lb in). Tighten screws in an X pattern.
- Tighten the bottom 2 mounting screws to 5 N.m (44 lb in).
- Connect the pump motor connector to the bottom of the EBCM.
- Connect the EBCM harness connector and depress the locking tab (1) to secure.
- Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .
- If installing a new EBCM, program the EBCM. Refer to Control Module References .
- Place the ignition switch in the RUN position. Do not start engine.
- Perform the Diagnostic System Check - Vehicle .
IMPORTANT:
Use only new wave springs and screws supplied with the new EBCM.
NOTE:
Refer to Fastener Notice
.