Generator Control Module Cable Cover Replacement

WARNING: This page is about a different variant/trim than selected.
Fig 1: Generator Control Module Cable Cover
GM2601907Courtesy of GENERAL MOTORS COMPANY
Generator Control Module Cable Cover Replacement

Callout Component Name
WARNING:

Ensure all High Voltage safety procedures are followed. Failure to follow the procedure exactly as written may result in serious injury or death.

WARNING:

Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.

The High Voltage Disabling procedure includes the following steps:

  • Identify how to disable high voltage.
  • Identify how to test for the presence of high voltage.
  • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.

Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:

  • Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.
  • Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.
    • Visually and functionally inspect the gloves before use.
    • Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.

Failure to follow the procedures may result in serious injury or death.

Preliminary Procedure Disable the high voltage system. Refer to High Voltage Disabling .
1 Generator Control Module Cable Cover Fasteners (Qty: 4)
CAUTION:

Refer to Fastener Caution .


Tighten 
9 (80 lb in)
2 Generator Control Module Cable Cover