Installation Procedure
- Clean the oil pump flow control valve sealing surface at the engine block.
- Install a NEW oil pump flow control valve seal (1).
- Install the oil pump flow control valve (2).
- Install the 3 oil pump flow control valve bolts (3) and tighten to 10 N.m (89 lb in).
- Connect the oil pump flow control valve wiring harness plug.
- Install the generator. Refer to Generator Replacement .
- Check and correct engine oil. Refer to Engine Mechanical Specifications .
CAUTION:
Refer to Fastener Caution .