Calibration Procedure
NOTE:
To complete the battery sensor module calibration, there must be no significant parasitic electrical drain on the battery. If the parasitic electrical drain does not remain below 100 mA for a 10 minute period during vehicle rest, the calibration will not be completed successfully. Refer to Battery Electrical Drain/Parasitic Load Test to correct any parasitic electrical drains.
NOTE:
If not diagnosing a Stop/Start concern and the negative battery cable was disconnected and reconnected, this procedure is not required. Inform the customer that the Stop/Start feature will not be available until the vehicle is allowed to sit for at least 3 hours undisturbed.
- Ignition OFF and all vehicle systems OFF. It may take up to 2 min for all vehicle systems to power down.
- Let the vehicle rest for a minimum of 3 hours without any interruptions (e.g. opening vehicle door, operating vehicle components, using fob buttons etc.).
- Engine CRANK.