LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Buick >> 2016 >> Envision >> Repair and Diagnosis >> External Pages >> Different car >> Section 20 (Hybrid/EV Control System) >> Diagnostic Information and Procedures >> DTC P06AF: Torque Management System Performance - Forced Engine Shutdown >> Circuit/System Testing
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Circuit/System Testing

WARNING: This page is about a different car, the 2015 Buick LaCrosse. However, it is still accessible from the selected car via links, so may be relevant.
  1. Verify that ECM DTC P0606 is not set.
  2. Ignition OFF, disconnect the K59 starter generator control module X3 connector and the K20 ECM X1 connector.
  3. Test for less than 1 Ω between the serial data circuits listed below:
    • K59 starter generator control module X3 connector terminal 16 and K20 ECM X1 connector terminal 36
    • K59 starter generator control module X3 connector terminal 17 and K20 ECM X1 connector terminal 37
    • If greater than the specified range, test the serial data circuit for an open/high resistance condition. If the circuit tests normal, replace the K20 ECM.
  4. If the DTC resets, program the K59 starter generator control module. If the DTC resets, replace the K59 starter generator control module.