LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 1999 >> Eldorado Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> On-Vehicle Testing >> Generator Functional Check
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Functional Check

  1. Ensure battery is in good condition and fully charged. Check connections at battery and generator. Repair as necessary. Turn off all electrical loads. Connect voltmeter to generator output. Run engine at 2500 RPM for 30 seconds. Check voltage output.
  2. With engine at normal operating temperature, voltage should be 13-15 volts. With cold engine, voltage should be 14-16 volts. If voltage is not as specified, replace generator. See GENERATOR  under REMOVAL & INSTALLATION. If voltage is as specified, connect inductive ammeter to battery charging cable. Connect carbon pile (VAT 40) across battery.
  3. Run engine at 2500 RPM. Adjust carbon pile to obtain maximum output from generator. If output is 125 amps or more, generator is okay. If output is less than 125 amps, replace generator. Run engine at idle. Adjust carbon pile to obtain maximum output from generator. If output is about 45 amps, generator is okay. If output is not about 45 amps, replace generator. See GENERATOR  under REMOVAL & INSTALLATION.