LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2002 >> Escalade EXT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1541 (HVAC System - Automatic) >> Specifications >> Sensor Resistance Table
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Sensor Resistance Table

WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Voltage Tech 2 (V) R Nominal (k ohms) Outside Air Temp (°F) Outside Air Temp (°C)
4.72-4.74 171.6 -22 -30
4.52-4.54 94.63 -4 -20
4.22-4.25 54.21 14 -10
3.81-3.85 32.00 32 0
3.31-3.34 19.61 50 10
2.76-2.79 12.31 68 20
2.22-2.25 7.959 86 30
1.73-1.75 5.268 104 40
1.31-1.34 3.563 122 50
0.99-1.01 2.458 140 60
The Tech 2 will display sensor value as a voltage. This gives the approximate voltage expected at different ambient temperatures as well as what should be read with an ohmmeter connected to the sensor. Since this is raw data any heat from underhood that changes ambient temp around the sensor might skew the reading, so let the engine compartment cool.