LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2005 >> CTS V >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 4 (Engine Controls - 3.6L - Introduction) >> Repair Instructions >> Accelerator Pedal Position (APP) Sensor Replacement >> Installation Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Installation Procedure

WARNING: This page is about a different variant/trim than selected.
    Fig 1: Aligning APP Sensor To Mounting Plate
    GM818887Courtesy of GENERAL MOTORS CORP.
  1. Position the APP sensor to the mounting plate.
  2. NOTE: Refer to Fastener Notice in Cautions and Notices.
  3. Install the APP sensor mounting bolts.

    Tighten:  Tighten the APP sensor mounting bolts to 9 N.m (80 lb in).

  4. Connect the APP sensor electrical connector.
  5. Operate the accelerator pedal and observe the APP angles using a scan tool. The accelerator pedal should operate freely, without binding between closed throttle and wide open throttle.
  6. Install the closeout/insulator panel. Refer to Closeout/Insulator Panel Replacement - Left in Instrument Panel, Gages and Console.