Installation Procedure
- Install the battery.
- Install the battery retainer and bolt.
Tighten: Tighten the battery retainer bolt to 17 N.m (13 lb. ft.).
- Install the battery vent tube (1) to the battery.
- Connect the battery positive cable (1) to the battery.
Tighten: Tighten the battery cable bolt to 17 N.m (13 lb. ft.).
- Connect the battery negative cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
NOTE:
Refer to Fastener Notice in Cautions and Notices.
IMPORTANT:
Ensure the vent tube (1) is properly routed through the floor pan grommet.