Circuit Description
Battery voltage is supplied directly to the evaporative emission (EVAP) canister vent solenoid valve. The control module grounds the EVAP canister vent solenoid valve control circuit to close the valve by means of an internal switch called a driver. The scan tool displays the commanded state of the EVAP canister vent solenoid valve as ON or OFF. The control module monitors the status of the driver. If the control module detects low voltage on the control circuit when the driver is commanded OFF, this DTC sets.
The following table illustrates the relationship between the ON and OFF states, and the OPEN or CLOSED states of the EVAP canister vent solenoid valve.
DTC P0498
| Control Module Command | EVAP Canister Vent Solenoid Valve Position |
|---|---|
| ON | Closed |
| OFF | Open |