Installation Procedure
- If the upper air cleaner housing was replaced only perform the following steps otherwise proceed to step 6.
- Install the MAF/IAT sensor.
- Install the MAF/IAT sensor bolts.
Tighten: Tighten the bolts to 4 N.m (35 lb ft).
- Install the air cleaner outlet duct.
- Tighten the air cleaner outlet duct clamp at the MAF/IAT sensor.
Tighten: Tighten the clamp to 3 N.m (27 lb in).
- Place the lower air cleaner housing over the studs and push down firmly in order to engage the grommets to the studs.
- Install the engine harness and PCM to the lower housing.
- Install the air cleaner upper housing.
- Engage the 3 integral clips (1) on the lower housing to the upper housing.
- Install the air cleaner outlet duct to the throttle body.
- Tighten the air cleaner outlet duct clamp at the throttle body.
Tighten: Tighten the clamp to 3 N.m (27 lb in).
- Connect the AIR pump inlet hose quick connect fitting to the air cleaner. Refer to Quick Connect Fitting(s) Service (Plastic Collar) .
- Connect the PCV fresh air tube quick connect fitting to the air cleaner outlet duct. Refer to Quick Connect Fitting(s) Service (Plastic Collar) .
- Connect the engine harness electrical connector to the MAF/IAT sensor.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.