Typical Scan Tool Data
Intake CMP Bank 1 Active
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Intake CMP Position Sensor Bank 1 5-Volt Reference Voltage | Incrementing from 0-255 counts | stops incrementing | stops incrementing | stops incrementing |
| Intake CMP Position Sensor Bank 1 Signal | Incrementing from 0-255 counts | stops incrementing | stops incrementing | - |
| Intake CMP Position Sensor Bank 1 Low Reference | Incrementing from 0-255 counts | - | stops incrementing | - |
Intake CMP Bank 2 Active
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Intake CMP Position Sensor Bank 2 5-Volt Reference Voltage | Incrementing from 0-255 counts | stops incrementing | stops incrementing | stops incrementing |
| Intake CMP Position Sensor Bank 2 Signal | Incrementing from 0-255 counts | stops incrementing | stops incrementing | - |
| Intake CMP Position Sensor Bank 2 Low Reference | Incrementing from 0-255 counts | - | stops incrementing | - |