Removal Procedure
- Disconnect the instrument panel (I/P) harness electrical connector (1) from the battery current sensor.
- Remove the negative battery cable. Refer to Battery Negative Cable Replacement (LC3) or Battery Negative Cable Replacement (LH2) or Battery Negative Cable Replacement (LY7) .
- Cut the tie straps and electrical tape attaching the battery current sensor to the battery cable.
- Squeeze the negative battery cable branches together.
- Slide the battery current sensor (1) off of the negative battery cable.
IMPORTANT:
Note the position of the battery current sensor prior to removal.