Typical Scan Tool Data
AIR Pressure Sensor
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions:
Ignition ON, Engine OFF Parameter Normal Range: BARO |
||||
| AIR 5-Volt Reference Voltage | BARO | 40 kPa | 40 kPa | 111 kPa |
| AIR Pressure Sensor Signal | BARO | 40 kPa | 40 kPa | 145 kPa |
| AIR Low Reference | BARO | BARO | 145-150 kPa | - |