Installation Procedure
WARNING: This page is about a different car, the 2010 GMC Sierra and 2010 Chevrolet Silverado. However, it is still accessible from the selected car via links, so may be relevant.
- Attach a lifting device (2 and 3) to the drive motor generator control module assembly at the three identified locations.
- Lift the drive motor generator control module assembly into the vehicle.
- Remove the lifting device and install the ball studs (1). Tighten the ball studs to 10 N.m (89 lb in).
- Install the drive motor generator control module assembly retainers (4) and mounting nuts (3). Tighten the mounting nuts to 9 N.m (80 lb in).
- Install the APM ground strap (1) and APM ground strap nut (2). Tighten the nut to 9 N.m (80 lb in).
- Install the sight shield circuit breaker (2) and secure with bolts (1). Tighten the bolts to 5 N.m (44 lb in).
- Connect the APM assembly connectors (1 and 3) and install any removed locking tabs.
- Connect the APM assembly connector (2) using the following procedure:
- Push the lever up.
- Install the connector (2) onto the terminals by pushing on the connector only.
- Rotate the lever after the terminals are engaged.
- Push the green tab to lock the lever.
NOTE: Install the connector (2) without disturbing the position of the lever. DO NOT use the lever to install the connector in place. - Remove the caps (3, 6) from the drive motor generator power inverter coolant pipes.
- Connect the drive motor generator power inverter module (PIM) cooling inlet and outlet hoses (4, 5).
- Install the shield circuit harness (1) and terminal fastener (2). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install the PIM 3 phase cables (3, 5) into the PIM distribution box with new seals (6).
- Install the PIM 3 phase cable mounting fasteners (2, 4). Tighten the mounting fastener to 9 N.m (80 lb in).
- Install the PIM 3 phase cable terminal fasteners (1). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install the HV dc battery cable (6) with seal (7) into the PIM distribution box.
- Install the HV dc battery cable mounting fasteners (5). Tighten the mounting fastener to 9 N.m (80 lb in).
- Install the high voltage (HV) dc battery cable terminal fasteners (2). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install the HV dc electric air conditioning compressor module (ACCM) cable (4) with seal (7) into the PIM distribution box.
- Install the HV dc electric ACCM cable mounting fasteners (3). Tighten the mounting fasteners to 9 N.m (80 lb in).
- Install the HV dc electric ACCM cable terminal fasteners (1). Tighten the terminal fastener to 9 N.m (80 lb in).
- Install a new seal (3) on the PIM distribution box.
- Clean the sealing surface of the 3 phase cable cover as necessary.
- Position the 3 phase cable cover (2) onto the PIM distribution box ensuring the seal remains in place.
- Tighten the 3 phase cable cover fasteners (1). Tighten the fasteners to 9 N.m (80 lb in).
- Connect the drive motor generator control module assembly connector (1).
- Fill the power electronics cooling system and test for leaks at all serviced connections. Refer to Generator Control Module Cooling System Draining and Filling .
- Install the sight shield. Refer to Drive Motor Generator Control Module Sight Shield Replacement .
- Install the fender cross brace. Refer to Front Fender Rear Upper Brace Replacement .
- Perform the High Voltage Enabling procedure. Refer to High Voltage Enabling .
- Install the air cleaner. Refer to Air Cleaner Assembly Replacement .
- For control module programming and setup procedures, refer to Control Module References .
CAUTION:
Refer to Fastener Caution
.
CAUTION:
Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.
CAUTION:
Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.
CAUTION:
Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.
NOTE:
DO NOT use excessively abrasive cleaning tools on the sealing surface. Hand sanding with wet 400 grit sandpaper or use of a hand scraper is recommended.