Garage Height Calibration
If any portion of the power liftgate assembly is replaced, repaired or disassembled, perform the following liftgate calibration procedure:
- Ensure that the rotary switch on the driver door panel is set to Garage.
- Open the liftgate to the desired height manually or by using the one of the following switches:
- The rotary switch on the driver door panel
- The unlatch switch on the liftgate handle
- The remote control switch on the key fob
- Hold the shutface switch for at least 3 seconds with the liftgate at the desired height.
- Close the liftgate completely using one of the following switches:
- The rotary switch on the driver door panel
- The shutface switch on the liftgate
- The remote control switch on the key fob