| Battery Hold Down Bracket Bolt |
9 N.m |
80 lb in |
| Battery Negative Cable Extension Cable Bolt (Body Ground) |
11 N.m |
97 lb in |
| Battery Negative Cable Extension Cable Bolt (Engine Block) |
22 N.m |
16 lb ft |
| Battery Negative Cable Clamp Nut |
7 N.m |
62 lb in |
| Battery Negative Cable Ground Bolt (Battery) |
22 N.m |
16 lb ft |
| Battery Negative Cable Ground Bolt (Engine Block - LTG) |
45 N.m |
33 lb ft |
| Battery Positive Cable Clamp Nut |
7 N.m |
62 lb in |
| Battery Positive Cable Nut (at battery fuse block) |
15 N.m |
11 lb ft |
| Battery Positive Cable Nut (at junction block) |
15 N.m |
11 lb ft |
| Battery Positive Cable Nut (at the starter) |
13 N.m |
115 lb in |
| Body Harness Terminal to Battery Negative Clamp Bolt |
7 N.m |
62 lb in |
| Generator BAT Terminal Nut |
22 N.m |
16 lb ft |
| Generator Mounting Bolt (LFX, LF3) |
58 N.m |
43 lb ft |
| Generator Mounting Bolt (LTG) |
22 N.m |
16 lb ft |
| Starter Motor Mounting Bolt (LFX, LF3) |
58 N.m |
43 lb ft |
| Starter Motor Mounting Bolt (LTG) |
22 N.m |
16 lb ft |
| Starter Shield Fasteners |
4.7 N.m |
42 lb in |
| Starter Solenoid B + Nut |
10 N.m |
89 lb in |