Oxygen Sensor
- Warm engine to normal operating temperature. Disconnect oxygen sensor connector.
- Connect voltmeter between oxygen sensor side terminal (of disconnected connector) and ground. See Fig 1 T apply voltage to oxygen sensor.
- With engine at 1500-2000 RPM, turn WOT microswitch on by moving microswitch lever. See Fig 2 that voltmeter reads about .8 volts.
- With engine at 1000-1500 RPM, disconnect vacuum hose at intake manifold. Check that voltmeter reads near zero. Reconnect vacuum hose and oxygen sensor connector.