Glow Plug Controller
- Ensure coolant temperature is less than 80°F (27°C) before beginning test. Place ignition switch in RUN position and allow glow plugs to cycle. After 2 minutes, crank engine for one second. It is NOT important that engine starts. Return ignition switch to RUN position. Glow plugs should cycle on at least once.
- If glow plugs do not cycle, disconnect controller (controller is located on top rear of valve cover). Connect test light between Pink/Black wire terminal of harness connector (terminal "A") and ground. See Figure . With ignition switch in RUN position, test light should be off. Test light should illuminate when engine is cranked.
- If test light does not illuminate as specified, repair short or open in engine harness Pink/Black wire. If test light illuminates as specified but glow plugs do not cycle, replace controller.