LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chevrolet >> 1997 >> Cavalier L4-2.2L VIN 4 >> Repair and Diagnosis >> Relays and Modules >> Relays and Modules - Instrument Panel >> Audible Warning Device Control Module >> Service and Repair
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Audible Warning Device Control Module: Service and Repair

MULTI-FUNCTION ALARM ASSEMBLY

Description:






REMOVE OR DISCONNECT
1. Negative battery cable.
2. Left sound insulator.
3. Nuts from alarm module.
4. Multi-function alarm assembly from convenience center.

INSTALL OR CONNECT
1. Multi-function alarm assembly to convenience center.
Tighten
^ Nuts to 6 Nm (53 lb. in.)
2. Nuts to alarm module.
3. Left sound insulator.
4. Negative battery cable.