Pull-In Windings Test

Connect test equipment as in hold-in windings test. See HOLD-IN WINDINGS TEST. See Fig 1 . Ground starter solenoid terminal "M". Turn switch on and quickly adjust carbon pile load until voltage reads as specified. Check ammeter reading. Turn off carbon pile and open switch. At 10 volts reading should be 60-85 amps. If ammeter reading is not as specified, replace starter solenoid.

Fig 1: Solenoid Winding Test Connections
G95G13470Courtesy of GENERAL MOTORS CORP.