Home >> Chevrolet >> 2001 >> Impala V6-3.4L VIN E >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Scan Tool Data, Normal Values and Definitions >> Scan Tool Data Definitions - Powertrain Systems >> HO2S 1
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

HO2S 1

The scan tool range is 0 to 1132 mV. This parameter represents the fuel control exhaust oxygen sensor output voltage. Should fluctuate constantly within a range between 10 mV, lean exhaust, and 1000 mV, rich exhaust, while operating in closed loop.