Installation Procedure
- Install the MAF sensor (5) into the air intake ducts.
- Tighten the clamps (1) on the MAF sensor.
Tighten: Tighten the clamps to 4 N.m (35 lb in).
- Connect the MAF sensor harness connector.
IMPORTANT:
Ensure that the MAF sensor flow arrows point away from the air cleaner assembly.
NOTE:
Refer to Fastener Notice in Cautions and Notices.