Scan Tool Data Definitions
- GEN F-Terminal Signal
-
The scan tool displays 0-100%. The scan tool displays 0-10% until the engine is started and the PCM receives a signal from the generator then the percentage varies up to 100%.
- GEN L-Terminal Signal Command
-
The scan tool displays On/Off. The scan tool displays Off until the engine is running, then the PCM supplies then the percentage value varies depending on electrical loads.
- GEN L-Terminal Signal Command
-
The scan tool displays On/Off. The scan tool displays Off until the engine is running, then the PCM supplies a 5.0 V signal to turn ON the regulator, then On is displayed.
- Ignition 1 Signal
-
The scan tool displays 0-20 Volts. The scan tool displays the voltage as received on the Ignition 1 circuit to the PCM.
- TR Sw.
-
The scan tool displays Park, Reverse, Neutral, Drive 4, Drive 3, Drive 2, Drive 1. The scan tool displays the position of the transmission range switch.