Installation Procedure
WARNING: This page is about a different car, the 2008 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
- If the generator control module was replaced. install the transaxle auxiliary pump control module. Refer to Auxiliary Fluid Pump Control Module Replacement .
- Position the generator control module (1) to the bracket (3), and install the generator control module bracket to module bolts (2).
Tighten: Tighten the bolts to 10 N.m (89 lb in).
- Install the generator control module (with bracket) (2) to the vehicle.
- Install the generator control module bracket nuts.
Tighten: Tighten the nuts to 10 N.m (89 lb in).
- Install the generator control module ground strap (2) to the stud and install the ground strap nut (1) to the module.
Tighten: Tighten the nut to 10 N.m (89 lb in).
- Connect the engine wiring harness electrical connector (1) to the transaxle auxiliary pump.
- Place a NEW terminal block seal onto the generator control module.
- Install the generator control module 3-phase cable terminal block (2) onto the generator control module.
- Install the generator control module 3-phase cable terminal block nuts (1) until snug.
- Tighten the generator control module 3-phase cable terminal block nuts in the sequence shown.
Tighten: Tighten the nuts to 8 N.m (71 lb in).
- Place a NEW terminal block seal onto the generator control module.
- Unsecure, and position the 36-volt terminal block (2) to the generator control module.
- Install the 36-volt terminal block nuts (1) to the generator control module.
Tighten: Tighten the nuts to 10 N.m (89 lb in).
- Place the generator control module cover (2) on top of the generator control module and tighten bolts (1).
Tighten: Tighten the bolts to 10 N.m (89 lb in).
- Install the generator control module coolant outlet hose (2) to the generator control module.
- Position the generator control module coolant outlet hose clamp (1) at the generator control module using the J 38185 or equivalent.
- Install the generator control module coolant inlet hose (2) to the generator control module.
- Position the generator control module coolant inlet hose clamp (1) at the generator control module using the J 38185 or equivalent.
- Install the generator control module bracket reinforcement (3).
- Install the generator control module bracket reinforcement bolt (1) and nuts (2).
Tighten: Tighten the bolt/nuts to 10 N.m (89 lb in).
- Connect the 2 engine wiring harness electrical connectors (2) to the generator control module.
- Install the 2 CPA retainers (3).
- Position and install the power brake booster vacuum hose (2) to the intake manifold.
- Position the power brake booster vacuum hose clamp at the intake manifold.
- Install the power brake booster vacuum hose to the clamp (2) to the generator control module coolant outlet hose.
- Install the battery tray. Refer to Battery Tray Replacement (LAT) .
- Fill the cooling system. Refer to Cooling System Draining and Filling (LAT Static Fill) .
- Connect the hybrid battery. Refer to Hybrid Battery Service Disconnect/Connect .
- If the generator control module was replaced, program the NEW module. Refer to Control Module References .
- Using a Tech 2, command an autostart in order to verify that the system is working properly.
NOTE:
Refer to Fastener Notice
.
Fig 5: View Of Generator Control Module 3-Phase Cable Terminal Block Nuts & Generator Control Module