LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chevrolet >> 2005 >> SSR Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 214 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> Scan Tool Data Definitions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Scan Tool Data Definitions

WARNING: This page is about a different car, the 2005 Chevrolet Corvette. However, it is still accessible from the selected car via links, so may be relevant.
A/C Refrigerant Pressure Sensor

The scan tool displays 0-3450 kPa (0-500 psi). The voltage applied to the ECM input from the A/C refrigerant pressure sensor is converted to a pressure value.

A/C Refrigerant Pressure Sensor

The scan tool displays 0-5 volts. The voltage applied to the ECM input for the A/C refrigerant pressure sensor.

A/C Relay Command

The scan tool displays Yes/No. The scan tool displays the control decision for the compressor clutch relay output as determined by the ECM.

A/C Request

The scan tool displays Yes/No. The scan tool displays Yes when the HVAC control module requires the A/C compressor clutch to engage. The scan tool displays No when the HVAC control module does not need the A/C compressor clutch to engage.

A/C Request Signal

The scan tool displays Yes/No. The scan tool displays Yes when the ECM receives a class 2 message from the HVAC control module to engage the A/C compressor clutch. The scan tool displays No when the ECM receives a class 2 message from the HVAC control module to disengage the A/C compressor clutch.

Afterblow Option

The scan tool can activate the afterblow feature and will display an * if the feature is activated.

Ambient Air Temp. Sensor

The scan tool displays -40 to 60°C (-40 to 140°F). The voltage applied to the HVAC control module input from the ambient air temperature sensor is converted to an unfiltered temperature value.

Blower Motor Speed

The scan tool displays 0-100 %. The actual blower speed interpreted by the HVAC control module.

Blower Motor Speed Command

The scan tool displays 0-100 %. The blower speed being requested by the HVAC control module.

Calibration ID

The scan tool displays the current level of calibration in the HVAC module.

Compressor Clutch Status

The scan tool displays Off/Auto. The scan tool displays Off when the HVAC control module is not using A/C system for cooling requirements. The scan tool displays Auto when the HVAC control module is using A/C system for cooling requirements.

Driver Program Number

The scan tool displays 0-255 Counts. This value will vary, depending on the air delivery mode and the air discharge temperature selected by the driver. The higher the program number will relate to a higher heating requirement.

Driver Temp. Dr. Cal. Range

The scan tool displays 0-65535 Pulses. The total calibrated range of the actuator that is stored in the memory of the HVAC control module.

Driver Temp. Dr. Motor Command

The scan tool displays 0-255 Counts. The desired position of the left air temperature actuator.

Driver Temp. Dr. Position

The scan tool displays 0-255 Counts. The signal output from the feedback potentiometer on the left air temperature actuator.

Driver Temp. Dr. Position

The scan tool displays 0-65535 Pulses. The signal output from the feedback potentiometer on the left air temperature actuator.

ECT Sensor

The scan tool range is -40 to +150°C (-40 to +302°F). This parameter indicates the engine coolant temperature based on input from the engine coolant temperature sensor.

Inside Air Temp. Sensor

The scan tool displays -40 to 60°C (-40 to 140°F). The voltage applied to the HVAC control module input for the inside air temperature sensor is converted to a temperature value.

LED Intensity

The scan tool displays 0-255 Counts. This parameter gives an indication of the intensity of the LED of the HVAC control module. The higher the count value the brighter the LED is.

A/C Off for WOT

The scan tool displays Yes/No. The scan tool displays Yes when the ECM recognizes wide open throttle. The scan tool displays No in all other throttle positions.

A/C Pressure Disable

The scan tool displays Yes/No. The scan tool displays Yes when the ECM recognizes an A/C pressure of 4.5 volts (400 psi). The scan tool displays no when less than 4.5 volts (400 psi) is recognized.

Left Sunload Sensor

The scan tool displays 0-255 Counts. The voltage applied to the left sunload input of the HVAC control module is converted to a number between 0-255. A high light intensity will produce a low count value.

Load Management Status

The scan tool displays On/Off. On will be displayed when a low battery condition is detected and one or more accessories have been disabled in order to reduce the electrical load.

Lower Left Duct Temp. Sensor

The scan tool displays 0-255 Counts. The voltage applied to the lower left duct air temperature input of the HVAC control module is converted to a number between 0-255. The higher the duct air temperature the lower the count value.

Lower Right Duct Temp. Sensor

The scan tool displays 0-255 Counts. The voltage applied to the lower right duct air temperature input of the HVAC control module is converted to a number between 0-255. The higher the duct air temperature the lower the count value.

Mode Dr. Cal. Range

The scan tool displays 0-65535 Pulses. The total calibrated range of the actuator that is stored in the memory of the HVAC control module.

Mode Dr. Motor Command

The scan tool displays 0-255 Counts. The desired position of the mode actuator.

Mode Dr. Position

The scan tool displays 0-255 Counts. The signal output from the feedback potentiometer on the mode actuator.

Mode Dr. Position

The scan tool displays 0-65535 Pulses. The signal output from the feedback potentiometer on the mode actuator.

Mode Status

The scan tool displays Off, Auto, Defrost, Heater, Defog, Bi-level and Mid. The scan tool displays the state of mode operation.

Psgr. Program Number

The scan tool displays 0-255 Counts. This value will vary, depending on the air delivery mode and the air discharge temperature selected by the passenger. The higher the program number will relate to a higher heating requirement.

Psgr. Temp. Dr. Cal. Range

The scan tool displays 0-65535 Pulses. The total calibrated range of the actuator that is stored in the memory of the HVAC control module.

Psgr. Temp. Dr. Motor Command

The scan tool displays 0-255 Counts. The desired position of the right air temperature actuator.

Psgr. Temp. Dr. Position

The scan tool displays 0-255 Counts. The signal output from the feedback potentiometer on the right air temperature actuator.

Psgr. Temp. Dr. Position

The scan tool displays 0-65535 Pulses. The signal output from the feedback potentiometer on the right air temperature actuator.

Recirculation Dr. Cal. Range

The scan tool displays 0-65535 Pulses. The total calibrated range of the actuator that is stored in the memory of the HVAC control module.

Recirculation Dr. Motor Command

The scan tool displays 0-255 Counts. The desired position of the recirculation actuator.

Recirculation Dr. Position

The scan tool displays 0-255 Counts. The signal output from the feedback potentiometer on the recirculation actuator.

Recirculation Dr. Position

The scan tool displays 0-65535 Pulses. The signal output from the feedback potentiometer on the recirculation actuator.

Right Sunload Sensor

The scan tool displays 0-255 Counts. The voltage applied to the right sunload input of the HVAC control module is converted to a number between 0-255. A high light intensity will produce a low count value.

Software Part Number

The scan tool displays the current level of software in the HVAC module.

Upper Left Duct Temp. Sensor

The scan tool displays 0-255 Counts. The voltage applied to the upper left duct air temperature input of the HVAC control module is converted to a number between 0-255. The higher the duct air temperature the lower the count value.

Upper Right Duct Temp. Sensor

The scan tool displays 0-255 Counts. The voltage applied to the upper right duct air temperature input of the HVAC control module is converted to a number between 0-255. The higher the duct air temperature the lower the count value.

Valet Switch

The scan tool displays Active/Inactive. This is the actual state of the Valet switch.

Vehicle Speed

The scan tool range is 0-255 km/h (0-158 mph). This parameter indicates the vehicle speed calculated by the ECM from the vehicle speed sensor (VSS).