HVAC Control Module Connector End Views
HVAC Control Module C1
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit No. | Function |
| 1 | D-BU | 1646 | Auxiliary Air Temperature Door Position Signal |
| 2-4 | Not Used | ||
| 5 | BN/WH | 230 | Instrument Panel Lamps Dimming Control |
| 6-7 | - | - | Not Used |
| 8 | YE | 1791 | Low Reference |
| 9 | WH/BK | 1236 | Auxiliary Air Temperature Door Control |
| 10 | D-BU | 1199 | Air Temperature Door Control |
| 11 | L-BU | 292 | Rear Defog Switch Signal |
| 12 | D-GN/WH | 762 | A/C Request Signal |
| 13 | PK/WH | 1648 | Recirculation Door Control A |
| 14 | L-GN/BK | 1647 | Recirculation Door Control B |
| 15 | D-BU/BK | 1688 | 5-Volt Reference |
| 16 | L-BU | 733 | Air Temperature Door Position Signal |
HVAC Control Module C2
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit No. | Function |
| 1 | OG | 52 | Blower Motor High Control |
| 2 | L-BU | 72 | Medium 2 Blower Motor Control |
| 3 | OG | 52 | Blower Motor High Control |
| 4 | L-BU | 72 | Medium 2 Blower Motor Control |
| 5 | BK | 2250 | Ground |
| 6 | TN | 63 | Blower Motor Medium 1 Control |
| 7 | BK | 2250 | Ground |
| 8 | YE | 60 | Blower Motor Low Control |
| 9 | BK | 2250 | Ground |
| 10 | BN | 341 | Ignition 3 Voltage |
| 11 | Not Used | ||
| 12 | OG | 4340 | Battery Positive Voltage |