HVAC Control Module Connector End View C2 (C67)
HVAC Connector End Views
Connector Part Information
|
Terminal Part Information
|
HVAC Control Module C2 (C67)
| Pin | Wire Color | Circuit No. | Function |
|---|---|---|---|
| 1-3 | - | - | Not Used |
| 4 | GY/BK | 754 | Blower Motor Speed Control |
| 5 | L-GN | 2275 | Mode Door Position Signal |
| 6 | - | - | Not Used |
| 7 | PK/WH | 1648 | Recirculation Door Control A |
| 8 | D-BU | 1646 | Auxiliary Air Temperature Door Position Signal |
| 9-14 | - | - | Not Used |
| 15 | TN | 2273 | Mode Door Control |
| 16 | - | - | Not Used |
| 17 | L-GN/BK | 1647 | Recirculation Door Control B |
| 18 | WH/BK | 1236 | Auxiliary Air Temperature Door Control |
| 19-20 | - | - | Not Used |
| 1-2 | - | - | Not Used |
| 3 | WH/BK | 1236 | Auxiliary Air Temperature Door Control |
| 4 | D-BU | 1646 | Auxiliary Air Temperature Door Position Signal |
| 5 | L-GN/BK | 1647 | Recirculation Door Control B |
| 6 | PK/WH | 1648 | Recirculation Door Control A |
| 7 | GY/BK | 754 | Blower Motor Speed Control |
| 8 | TN | 2273 | Mode Door Control |
| 9 | L-GN | 2275 | Mode Door Position Signal |
| 10-16 | - | - | Not Used |