Installation Procedure
- Insert the ABS brake pressure modulator valve into the mounting bracket and install the nuts.
Tighten: Tighten the nuts to 15 N.m (11 lb ft) .
- Remove the screw plugs and install all of the hydraulic brake pipes.
Tighten: Tighten the brake pipe nuts to 22 N.m (16 lb ft) .
- Connect the 31-pin wiring harness connector J1.
- Connect the negative battery cable.
- Bleed the hydraulic system. Refer to Hydraulic Brake System Bleeding (ABS) or Hydraulic Brake System Bleeding (Manual) .
- Refer to Control Module References for programming and setup information.
NOTE:
Refer to Fastener Notice
.