Circuit/System Testing
- Verify that a test lamp illuminates between the generator B+ terminal X2 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, disconnect the X1 harness connector at the generator.
- Ignition ON, test for less than 1 V between the control circuit terminal 1 and ground.
- If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Engine running, command the L-Terminal ON to 85% with a scan tool. Test for greater than 3 volts between the control circuit terminal 1 and ground.
- If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If the circuit tests normal, replace the generator.