Installation Procedure
- If the sensor is being reused, apply thread sealant GM P/N 12345382 (Canadian P/N 10953489) or equivalent, to sensor threads.
- Install the ECT sensor.
Tighten: Tighten the sensor to 23 N.m (17 lb ft).
- Connect the ECT sensor harness connector. Push in the connector until a click is heard, then pull back to confirm a positive engagement.
- Install the fuel injector sight shield. Refer to Fuel Injector Sight Shield Replacement .
- Fill the engine cooling system to proper level. Refer to Cooling System Draining and Filling (LNJ GE 47716 Fill) or Cooling System Draining and Filling (LNJ Static Fill) .
NOTE:
Tap out sensor mounting hole in engine head to remove any thread sealant residue. Clean any sealant residue from old sensor if the sensor is going to be reused.
CAUTION:
Refer to Component Fastener Tightening Caution
.