Circuit/System Description
A restricted or blocked evaporative emission (EVAP) vent path is detected by the control module commanding the purge valve ON (open) and the vent valve ON (closed) allowing a vacuum to be applied to the EVAP system. Once a calibrated vacuum level has been reached, the control module commands the purge valve OFF (closed) and the vent valve OFF (open) while monitoring the fuel tank pressure (FTP) sensor for a decrease in vacuum.
The following table illustrates the relationship between the ON and OFF states, and the OPEN or CLOSED states of the EVAP canister purge and vent valves.
| Control Module Command | EVAP Canister Purge Valve | EVAP Canister Vent Valve |
|---|---|---|
| ON | Open | Closed |
| OFF | Closed | Open |