Circuit/System Testing
- Ignition OFF, disconnect the EVAP purge solenoid valve harness connector.
- Engine idling, command the EVAP vent valve closed with a scan tool.
- Increase the engine speed to 1, 200-1, 500 RPM. Verify the scan tool fuel tank pressure (FTP) sensor parameter is -0.9 to +0.9 mmHg (-0.5 to +0.5 in.H2O).
- If not within the specified range, replace the EVAP purge solenoid valve.
- Ignition OFF, remove the fuel fill cap. Connect the GE-41415-50
to the fuel tank filler neck. Connect the J 41413-200
to the GE-41415-50
. See Special Tools
.
- Ignition ON, command the EVAP vent solenoid valve closed with a scan tool.
- Pressurize the EVAP system with nitrogen to 9.33 mm/Hg (5 in/H2O). Compare the scan tool Fuel Tank Pressure Sensor parameter to the J 41413-200
pressure/vacuum gage. See Special Tools
. Verify the FTP sensor parameter is within +/-0.9 mmHg (+/-0.5 in.H2O) of the pressure/vacuum gage.
- If not within the specified range, replace the FTP sensor.
- Command the EVAP vent solenoid valve OPEN with a scan tool. Verify the scan tool FTP sensor parameter is -0.9 to +0.9 mmHg (-0.5 to +0.5 in.H2O).
- If not within the specified range, test or replace the EVAP canister vent solenoid valve and vent pipe for a blockage or restriction.