Fastener Tightening Specifications
| Application | Specification | |
|---|---|---|
| Metric | English | |
| Battery Hold-Down Retainer Bolt | 25 N.m | 18 lb ft |
| Generator Bolt | 22 N.m | 16 lb ft |
| Generator Terminal Nut | 20 N.m | 15 lb ft |
| Junction Block Terminal Nut | 15 N.m | 11 lb ft |
| Negative Battery Cable Bolt | 20 N.m | 15 lb ft |
| Negative Battery Cable Nut | 15 N.m | 11 lb ft |
| Positive Battery Cable Nut | 15 N.m | 11 lb ft |
| Positive/Negative Battery Cable Ground Nut | 10 N.m | 89 lb in |
| Starter Bolt | 40 N.m | 30 lb ft |
| Starter Solenoid Nut | 17 N.m | 13 lb ft |
| Starter Solenoid S Terminal Nut | 3 N.m | 27 lb in |