Generator Replacement (LS3/L99)
| Callout | Component Name |
|---|---|
|
Preliminary Procedure
|
|
| 1 | Nut
CAUTION:
Refer to Fastener Caution
.
Tighten: 15 N.m (11 lb ft) |
| 2 | Generator battery positive cable |
| 3 | Bolt (Qty: 2) Tighten: 58 N.m (43 lb ft) |
| 4 | Generator Procedure: Disconnect the engine harness generator connector. |