Dynamic Test
- Remove the appropriate Q6 camshaft position actuator solenoid valve.
- Install a 10 A fused jumper wire between the control circuit terminal 2 and 12 V. Momentarily install a jumper wire between the low reference terminal 1 and ground. The pintle should extend.NOTE:
- The camshaft position actuator solenoid pintle should be facing downward for this test.
- Do not allow electrical current to flow through the camshaft position actuator solenoid for greater than 1-2 s.
- If the function does not perform as specified, replace the Q6 camshaft position actuator solenoid valve.