Removal Procedure
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
- Remove the accessory drive belt. Refer to Drive Belt Replacement - Accessory (LSA)
.
Courtesy of GENERAL MOTORS COMPANY
- Remove the protective boot (1) and remove the battery positive fastener (2) at the back of the generator.
- Remove the battery positive cable fastener (2) and remove the battery positive cable (3), from the back of the generator.
- Disconnect the engine harness connector (4).
Courtesy of GENERAL MOTORS COMPANY
- Remove the lower generator mounting fastener (1) and the generator mounting stud (3).
- Remove the upper generator mounting fasteners (2).
Courtesy of GENERAL MOTORS COMPANY
- Remove the generator (1) from the engine compartment.