Drive Motor Battery Interface Control Module Replacement (Module 2)
| Callout | Component Name |
|---|---|
|
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed. The High Voltage Disabling procedure includes the following steps:
Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
Failure to follow the procedures may result in serious injury or death.
WARNING:
The Volt Battery Pack will utilize an exchange program. Please consult the most recent revision of bulletin/PI #PIP4841, available in Service Information (SI), for a list of approved Volt Battery Pack service procedures. Components that may be removed and serviced without exchanging the complete battery pack are identified in the bulletin/PI. Please contact the GM Technical Assistance Center if you have any questions. Preliminary Procedures
|
|
| 1 | Drive Motor Battery Interface Control Module Controller Procedure
NOTE:
Do not leave the orange hybrid/EV battery interface control module harness disconnected for more than one hour. Leaving the orange hybrid/EV battery interface control module harness disconnected for more than one hour will result in an unrecoverable unbalanced hybrid/EV battery section. |