Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Install the drive motor battery wire junction block relay (2) and tighten the fasteners (1) to 9 N.m (80 lb in).
- Connect the following to the generator battery disconnect relay junction block :
- Current Sensor Connector (3).
- Pre-Charge Contacts (4).
- Contactor Connector (5).
- Install the connector (1) to the generator control module.
- Install the fasteners (2) retaining the junction block to the generator control module.
- Position the high voltage cables through the cable retaining clip (1).
- Install the high voltage cables to the batteries and tighten the fasteners (3) to 9 N.m (80 lb in).
- Enable the hybrid battery. Refer to High Voltage Enabling .
CAUTION:
Refer to Fastener Caution .
NOTE:
Critical high voltage fastener. Perform second torque verification check following re-assembly.