Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Install the generator control module cover (3).
- Install the generator control module cover fasteners (1) and tighten to 9 N.m (80 lb in).
- Install the generator control module cover fastener (2) and tighten to 9 N.m (80 lb in).
- Install the drive motor battery cooling blower motor and bracket (2). Tighten the fasteners (1) to 9 N.m (80 lb in).
- Install the drive motor battery cooling blower outlet duct (1). Refer to Drive Motor Battery Cooling Blower Outlet Duct Replacement (LUK) .
- Install the high voltage 3-phase cable (2) to the generator control and battery module. Tighten the nuts (1) to 9 N.m (80 lb in).
- Install the 12V cable (3) to the generator control and battery module. Tighten the nut (4) to 9 N.m (80 lb in).
- Install the body harness connectors (1).
- Install the drive motor battery cooling air inlet duct (1). Refer to Drive Motor Battery Cooling Air Inlet Duct Replacement .
- Install the rear compartment floor panel front trim. Refer to Rear Compartment Floor Panel Front Trim Replacement (With HP6) .
- Install the rear compartment floor panel. Refer to Rear Compartment Floor Panel Trim Replacement (Without HP6) , Rear Compartment Floor Panel Trim Replacement (With HP6) .
- Install the drive motor battery cooling blower cover. Refer to Drive Motor Battery Cooling Blower Cover Replacement (With HP6) .
- Enable the hybrid battery. Refer to High Voltage Enabling .
NOTE:
Make sure the duct is flush against the seal for efficient generator control and battery module cooling.
NOTE:
Make sure the duct is flush against the seal for efficient generator control and battery module cooling.